Mastervolt marine

Far-off destinations - Catamaran (hybrid propulsion)

Your ship:

50-70 ft catamaran with electric propulsion

Use:

Long trips with many passengers

Details:

All luxury onboard facilities

Your sailing profile

A large catamaran gives you lots of space for luxury and comfort. You can also sail with friends and family or take a (professional) trip with large groups. Whoever joins you onboard will love the way everything is thought through with the Mastervolt system on this catamaran. Listening to music and making coffee as you enjoy the silent comforts of electric sailing through a bay, while the diving compressor fills the oxygen cylinders. By placing identical systems to port and starboard, your catamaran stays perfectly balanced in terms of both power and weight. Island hopping at full speed is one of many options at your disposal.

Your onboard consumers include:

DC consumers:

 

 

description

total x capacity x hour

daily consumption

E-propulsion

2 x 1500 Watt x 1 hour

= 3.00 kWh

Navigation and deck lighting

4 x 20 Watt x 8 hour

= 0.64 kWh

Navigation and communication equipment

6 x 40 Watt x 12 hour

= 2.88 kWh

Interior lighting

15 x 20 Watt x 4 hour

= 1.20 kWh

Water, shower, toilet and bilge pumps

8 x 150 Watt x 0.2 hour

= 0.24 kWh

Water maker

1 x 300 Watt x 4 hour

= 1.20 kWh

Electric winches

3 x 1500 Watt x 0 hour

= 0 kWh

Refrigerator

1 x 80 Watt x 8 hour

= 2.00 kWh

Several small consumers

4 x 20 Watt x 4 hour

= 0.32 kWh

 

 

 

AC consumers:

 

 

Microwave/oven

1 x 2000 Watt x 0.5 hour

= 1 kWh

Audio system

1 x 250 Watt x 4 hour

= 1 kWh

TV

3 x 150 Watt x 2 hour

= 0.9 kWh

Espresso machine

1 x 1200 Watt x 0.5 hour

= 0.6 kWh

Laptop

1 x 30 Watt x 0.2 hour

= 0.16 kWh

Household appliances

4 x 200 Watt x 0.2 hour

= 0.16 kWh

Washing machine

1 x 2500 Watt x 0 hour

= 0 kWh

Dishwasher

1 x 1000 Watt x 0 hour

= 0 kWh

Diving compressor

1 x 1000 Watt x 0 hour

= 0 kWh

Total DC and AC consumers

 

= 15.3 kWh

       

 

The Basics

  • All Mastervolt systems have been designed for faultless operation and complete user friendliness. Their reliability is unprecedented and on the rare occasions when something does go wrong our worldwide service network will quickly find a solution.
  • You want to be able to power all AC and DC consumers at least 24 hours independent of shore power.
  • The maximum AC capacity is 2000 Watt for the microwave/oven; however, you will only use this for a relatively short period of time.
  • The decentralised MasterBus system separates the consumers on the foreship, amidships and aft.
  • You require optimum ease of operation; centrally located.